Design Guidelines
Macquarie University Property

Staff Work Point

Staff work point

Space description

This space is designed as an individual workspace.

Adjacencies

This space is to be located within office / administration areas and be located to the side of main access pathways.

 

Example spaces

Typical Professional staff work point cluster:

[ Expand all ]

Components

Planning

Planning

Room and Spaces Planning Requirements To suit furniture layout.
- min. 1.5m wide space behind desk for access.
- min. 1.8m between desks in back-to-back arrangement.
Design occupancy Single Workpoint
Area To suit desk layout approximately 4.4m2 per workpoint plus circulation.
Other Positioned adjacent to office circulation area.

More information about Planning

Building fabric

General

General All finishes and colours selected to suit entire office aesthetic.
Design principles Best practice solutions to be provided for all workpoint arrangements, to suit building layout, operational requirements, and end user requirements.
Materials & finishes All finishes and colours specified are to suit entire office aesthetic.
Proprietary items Special furniture, fixture, or space allowances to be provided when specified by a WHS or statutory compliance requirement.

More information about building fabric General

Internal Walls

Wall Finish - Pinboard Finish to 2100mm high min. 1.8m wide
- White finish to non-feature walls - Natural White, Lexicon White, or Napkin White.
Other White boards or writable glass surfaces to workpoint clusters where requested by users.

More information about Internal Walls

Floors

General Selection Requirements To suit office fitout.
Preferred Material Selection Carpet tiles to match adjoining office spaces.
Carpet 500x500 tiles preferred
Resilient Floor Finishes CP - Carpet finish.
Other Ducted Skirting to perimeter

More information about Floors

Ceilings

Ceiling Finishes Set plaster, grid tiles, or acoustic panel, as required
Ceiling Heights Preferred minimum height: 2700mm above FFL.
Ceiling Selection

- Set plaster, grid tiles, or acoustic panel, as required.

- Preferred tiled system: 1200x600 grid.

Acoustic Ceilings Gridded accoustic tile ceiling Ecophon acoutic in white
NRC: 0.6 - 0.8 absorptive ceiling

More information about Ceilings

Openings

Windows

Window Selection Requirements Windows are required for this space. 
Observation Windows Maximise windows to adjacent corridor.
Visual Privacy - Blinds may be used to aid visual privacy.
- Frosting may be used on internal glass to aid visual privacy.
Other External glazing, sill height 1000mm min.
Internal safety glass glazing to adjacent circulation space for supervision from floor to 2.1m height

More information about Windows

Doors

Doors Type Fully glazed or glazed sidelight if door provided
Door Function Entry door lockable (if enclosed)
Glazing Glazed sidelight
Door Hardware Lock type
Office lock if enclosed
Keying / locking
Keyed to Differ (KD) (if door Provided)
Master keying
Master keyed - Administration & Staff (AF) (if Door Provided)

More information about Doors

Furniture

Furniture

General Design Principles - Work point desk, chair, and storage furniture required.
Desk Selection - Typical 1800 wide desk per work point.
- Typical white melamine finish to desk top.
Chair Selection - Ergonomic task chair suitable for long term (8 hours per day) seated tasks.
Storage Furniture- Choice of standard mobile pedestal or mobile tambour pedestal.  Both can be used where space provides.
- Optional open shelf to hang from partition.
- Proximity to 1m linear common storage furniture required per work point.
- 3m linear shelf space per work point required - in the vicinty of the work point.
Other- Partitions to be 1200mm above FFL and to be a pinnable surface.
- Colours/fabrics to suit surrounding office space selections.

More information about Furniture

Fixed Furniture

Whiteboards White boards or writable glass surfaces to workpoint clusters where requested by users.
Pinboards - Pinboard to workpoint clusters where requested by users.
- Pinboards can be fixed to rear of storage furniture adjoining desks.
- All partitions at work points to be pinnable surfaces.

More information about Fixed Furniture

Fittings

Signage

Design Principles -
Work Point Signage - Sliding plate name signage to be provided where requested by faculty/department.
- Plates to display as follows:
Line 1:   Name 1Line 2:   Name 2 (if required)Line 3:   Department/Office

More information about Signage

Security

Security

Security type / group B
Refer to Design Standard
CCTV Not Required
Access control Required to greater office area.
Intruder detection Not Required
Keying Refer to Doors

More information about Security

Acoustics

Acoustics

Noise level Consideration Required.  Minimise work point noise with material and product selection.
Noise emittance Low
Room to room Room to Room Acoustics should be reduced where possible.
Room acoustics Room reverberation time to be considered.

More information about Acoustics

Services

Ventilation

Natural ventilation Natural Ventilation as redundancy for mechanical
Manually Openable Windows
Supply air AS 1668 Supply Rate
Controls Set points to greater office areas, as per mechanical design spec.

More information about Ventilation

Conditioning

Mechanical cooling Air Conditioning
Conditioned Space
Mechanical heating Provide Heating to MQU Standard
Conditioned Space
Controls - Commensurate with building system
- Reed Switch To Openable Windows / Louvres
- User control for the air conditioning units are to be located adjacent to the light switch in each room to enable the unit to be turned on or off.
Other -

More information about Conditioning

Fire protection

General- Fire protection to be considered as part of overall office design.
- All fire protection requirements should refer to Australian Standards, BCA, and any relevant alternative solutions
Fire detection To Code Requirements
Fire suppression FIRE HOSE REEL
To Code Requirements
EWIS To Code Requirements
Portable fire equipment PORTABLE FIRE EXTINGUISHER/ BLANKET
To Code Requirements

More information about Fire protection

Illumination

Lighting / lux levels - 240 lux desired over work point surfaces.
- To Code Requirements
Lighting controls - Managed by BMS
- Movement sensors to open plan perimeter areas
- Movement sensors to single/shared offices
- Manual overrides
Other -Task lighting to workpoint can be added at
Natural Light - DaylightNatural daylight to room is desirable

More information about Illumination

Power

Type Soft Wired GPOs to work points
Quantity Minimum 2 double GPO's per work point
Other Ducted Skirting
Power on ducted skirting.
Cable management to be considered.

More information about Power

Communication / AV

Voice - 2 data points required per workpoint
- Avaya phone handset supplied by MQ IT dept.
Data - 2 data points required per workpoint
WAP - Wireless access to entire floor required
Other - AV requirements determined for entire office space

More information about Communication / AV