Sanitary fixtures
The following are the preferred sanitary fixtures to be included.
Refer to Fixtures for information on other associated fixtures.
Performance requirements as listed are to be met by any item used irrespective of whether the preferred fixture or an approved alternative is used.
All Sanitary Fixtures are to be rated based on the Water Efficiency Labelling and Standards (WELS) Scheme and as prescribed in AS6400.
Minimum Star rating based on Table 3.1 of AS 6400
Sanitary fixtures schedule
Urinals
Urinal Fixture | |||
---|---|---|---|
Location | Performance Requirement | Preferred Fixture | Alternative Fixture |
Student Area | Wels 6 Star rating |
Caroma Cube3 0.8 litre Electronic activation urinal suite with tamper-proof supply faucet. | Caroma H2Zero waterless Urinal Suite |
Staff Area | Wels 6 Star rating |
Caroma Cube3 0.8 litre Electronic Activation urinal suite | Caroma H2Zero waterless Urinal Suite |
Flushing of urinals is to be controlled by Caroma Smart demand urine sensing Cube 3 or Leda Electronic.
Hand Basins
Hand Basin | |||
---|---|---|---|
Location | Preferred Fixture | Alternative Fixture | |
Student Area | Caroma vitreous china, 'Caravelle' pattern in white | Tapholes to suite | |
Staff Area | Caroma vitreous china, 'Caravelle' pattern in white | Tapholes to suite | |
Accessible WC's | Caroma vitreous china, 'Caravelle' pattern in white | Tapholes to suite | Caroma Vitreous china Cube Extension Wall Basinin white |
Laboratory & Preparation rooms Hand basins |
Caroma vitreous china, 'Caravelle' pattern in white With Bottle trap | Tapholes to suite |
WC Suites
WC Suites to be silicon fixed throughout all locations.
WC Suites | |||
---|---|---|---|
Location | Performance Requirement | Preferred Fixture | Alternative Fixture |
Student Area | Wels 4 Star rating | Caroma Trident Sovereign 2000 vitreous china suite with 4.5/3litre dual flush cistern with tamper-proof supply faucet. | Caroma Leda wall faced close coupled suite with Leda 2000 4.5/3 litre dual flush cistern with tamper-proof supply faucet. |
Staff Area | Wels 4 Star rating | Caroma Trident Sovereign 2000 vitreous china suite with 4.5/3 litre dual flush cistern. | Caroma Leda wall faced close coupled suite with Leda 2000 4.5/3 litre dual flush cistern. |
Ambulant WC | Wels 4 Star rating | Caroma Leda Care Invisi wall faced toilet suite with concealed 4.5/3 litre dual flush cistern & seat to AS1428.1. for ambulant WC. | |
Accessible WC's | Wels 4 Star rating | Caroma Leda Care Invisi wall faced toilet suite with backrest, concealed 4.5/3 litre dual flush cistern & seat to AS1428.1. |
Cleaner's Sink
Cleaners sinks where nominated in room data are to be Heavy duty Caroma/Fowler white vitreous china sink 575mm x 435mm with C.P. hinged bucket, grating and timber or rubber guard fixed to front edge 51mm C P outlet plug, chain and washer. Set front edge of sink 480mm above FFL.
Cleaners Sink | |||
---|---|---|---|
Location | Preferred Fixture | Supplier | Alternative Fixture |
Cleaners Sink |
Caroma cleaners sink with rubber rest pad, bracket, hinged grating and plug. No tapholes Code: 811592W (sink) - 811593 (grate) - 811595 (fixing bracket) - 687031 (plug and waste) |
GWA Group t: 1300 227 662 |
Stainless Steel Sinks
Stainless Steel Sink to be provided in staff tea rooms and teapoints. To be polished s.s. single bowl sink and drainer units with centre bowl, C.P. outlet, plug chain and washer. Drainer to have upstand and skirting at back and ends as appropriate. Each unit to be fitted with 152mm dia. S.s. tea leaf strainer and matching bowl on one drainer, with waste connected to sink bowl waste.
Stainless Steel Sinks | |||
---|---|---|---|
Location | Preferred Fixture | ||
Teapoint | Polished s.s. single bowl sink and drainer units with centre bowl or end bowl | Tapholes to suite tapset | Include Stainless Steel Basket Waste & Strainer |
Tea / Lunch Room | Polished s.s. Double bowl sink and drainer units with centre bowl | Tapholes to suite tapset | Include Stainless Steel Basket Waste & Strainer |
Clark Monaco Stainless Steel Sink unit Double 20 litre end bowl with 1 taphole. Includes stainless steel basket waste. |
GWA Group t: 1300 227 662 | Kitchen / Staff room |
Laboratory Sinks
Include Laboratory Sinks to the following rooms;
- Damp Laboratories, include Laboratory Sinks to perimeter benches of Laboratory room. Minimum of one for every four occupants.
- To Wet Laboratories, include Laboratory sinks to perimeter and central benches. Minimum of one for every two occupants
- To be polished s.s. single bowl sink and drainer units with centre bowl, C.P. outlet, plug chain and washer. Drainer to have upstand and skirting at back and ends as appropriate. Each unit to be fitted with 152mm dia. S.s. tea leaf strainer and matching bowl on one drainer, with waste connected to sink bowl waste
- All Laboratory sinks are to be stainless steel unless Dry Ice will not be used in the Laboratory, where Polly Propylene can be used.
Laboratory Sinks | |||
---|---|---|---|
Location | Preferred Fixture | ||
Damp & Wet Laboratories | Polished s.s. single bowl sink | Tapholes to suite tapset | Include Stainless Steel Basket Waste & Strainer |
Taps
Taps | |||
---|---|---|---|
Location | Preferred Fixture | Performance Requirement | Alternative Fixture |
Student Area Shower | Lever Mixer | ||
Student Area Basins |
Cold water pillar tap by Presto Model No. P2000 Hot water pillar tap by Presto model No. 2020 Hot & cold mixing tap Prestomix model No. P20517 | Wels 6 Star. | |
Staff Area Shower |
Oras Vega Shower Mixer including body, fascia and handle with hot/cold indicator Enware Code: SLM608 | Shower Fittings Satin chrome plated Raymor 'Levermixer' vandal proof pattern. | |
Staff Area Basins | |||
Accessible Shower |
Chrome hand held shower and 1.5m smooth hose with right hand inverted T stainless steel grab rail, elbow & chrome plated adjustable shower head holder. Wall outlet to have backflow prevention device Note: To be paired with MIX3 Oras Vega Shower Mixer including body, fascia and handle with hot/cold indicator Enware Code: SLM608 |
WELS 3 Star. Installation to comply with AS1428.1-2009 | |
Accessible Basin |
Caroma, Liano Nexus basin mixer in chrome finish. Handicapped Toilet Basins to have Raymor 'levermixer' taps | WELS 6 Star | |
Staff Area Sink Student Area Sink |
Zip Hydrotap G4 with tall mixer (four in one) Or Raymor M1 sink single lever sink mixer where wall mounted BWU included. | WELS 3 Star | |
Kitchen Basin mixer |
Caroma, Liano Nexus basin mixer in chrome finish. Code: 96193C6A | WELS 6 Star | |
Internal Stop Cock | Internal stop cocks to be Raymor Capstan pattern. One stopcock to both hot and cold to each fitting. | Raymor | |
Shower head General showers - Ground floor WC's |
Delabie Tonic Jet vandal resistant shower head Chrome plated Shower head angle can be set by installer note: to be paired with MIX2 | WELS 3 star / 8lpm | Enware |
Cleaner sink tap |
CS Recess Set with SP110 Swivel Spout - 1/4 turn ceramic disc - bright chrome finish Enware | WELS 3 Star | Enware |
Note: All taps except Academy are to be ceramic seal quarter turn movement, both hot and cold rotating in the same direction (clockwise off).
Boiling Water Units
ZIP wall unit, capacity as required.
ZIP Boiling Units to use silicone fixing.
Boiling Water Unit | ||
---|---|---|
Location | Preferred Fixture | |
Teapoint Staff Lunchroom | Zip Wall Unit, capacity as required, or | |
Zip Hydrotap Model No. 2773, (underbench) or | ||
Zip Hydrotap G4 with tall mixer (four in one) boiling: 160 tea cups chilled: 175 glasses Code: HT1726 + 90026 (tap extension kit) | ZIP Industries | |
Chilled & Boiling Water unit |
Zip Hydrotap G4 with tall mixer (four in one) boiling: 240 tea cups chilled: 175 glasses Code: HT1727 + 90026 (tap extension kit) |
Floor Wastes
Floor wastes to be 102mm cast brass gully traps with 102mm dia. Bras inlet risers, 102mm dia.
Brass extension piece as required and C.P. brass screwed grating, all grouted
Drainage Protection and Survey
The specification is to require that the Builder:
- Provides protection to pipework below slabs on grade during concrete pours.
- Provides to the Superintendent a video of all drainage pipework under floor slabs shortly after the slab pours are complete.
- Effectively seals all sanitary outlets in the building during construction to avoid any foreign material being put into the drainage system.
- Provide a video of all drainage pipework before Practical Completion.
These precautions are in addition to the water tests and pipe capping normally required in hydraulics specifications.