Damp Lab Prep
Space description
The Damp Lab Preparation room is a supplementary
support space to the Teaching Laboratory.
Fixtures, tables, workbenches and cupboards are provided for the preparation of
experiments and the storage, cleaning and preparation, cleaning of materials,
apparatus and equipment.
Adjacencies
The Damp Preparation room should have access to and from the adjacent Laboratory(/ies).
[ Expand all ]
Components
Planning
Planning
Site factors | - |
---|---|
Room and Spaces Planning Requirements | - |
Design occupancy | - |
Area | - |
Other | - |
Building fabric
General
General | - |
---|---|
Design principles | - |
Materials & finishes | - |
Proprietary items | - |
More information about building fabric General
Materials & Finishes
- | - |
---|---|
- | - |
- | - |
More information about Materials & Finishes
Roof
- | - |
---|---|
- | - |
External Walls
- | - |
---|---|
- | - |
- | - |
More information about External Walls
Internal Walls
Impact Resistance | - |
---|---|
Fire Rating | - |
Wall Finish | - |
Other | - |
More information about Internal Walls
Floors
General Selection Requirements | - |
---|---|
Variations | - |
Preferred Material Selection | - |
Concrete | - |
Carpet | - |
Entry Floor Mats | - |
Floor Tiles | - |
Ceramic Tiles | - |
Resilient Floor Finishes | Marmoleum (Anti-Static) |
Other | Coved Vinyl Skirting |
Underfloor Ventilation
- | - |
---|---|
- | - |
- | - |
More information about Underfloor Ventilation
Ceilings
Ceiling Finishes | - |
---|---|
Ceiling Heights | - |
Ceiling Selection | - |
Acoustic Ceilings | - |
Non Combustible / Fire Rated | Non combustible ceiling linings are required |
Openings
Windows
Window Selection Requirements | - |
---|---|
Glazing | - |
Observation Windows | - |
Visual Privacy | - |
Window Furniture | - |
Other | - |
More information about Windows
Doors
Doors Type | Solid core entry door with viewing panel |
---|---|
Door Function | Entry door lockable |
Fire / Acoustic Rated | - |
Frame Type | - |
Glazing | Half glazed entry door. Glazed panels to Preparation room, 125mm wide by 600mm high with sill at 1200mm |
Door Hardware | Lock type Classroom lock |
Fixtures
Fixtures
General Design Principles | - |
---|---|
Amenities Fixtures | - |
Amenities for Mobility Impaired Persons | - |
Lecture Theatre Furniture & Fittings | - |
Cleaners Room & Store | - |
Connected | Caroma Basin with Enware Taps. |
Other | Fume Cupboard |
More information about Fixtures
Sanitary Fixtures
- | - |
---|---|
- | - |
Furniture
Furniture
General Design Principles | - |
---|---|
Recommended Furniture Selection | - |
Desk & Chair Selection | KPD lab bench - chemical resist laminex (Oyster Grey) Seating - Project specification |
More information about Furniture
Fixed Furniture
Door Entry Mats | - |
---|---|
Whiteboards | Whiteboard Type 1 |
Pinboards | - |
Notice Boards | - |
Projection Screens | - |
Kitchen & Tea Room Equipment | HWB only - Caroma + Enware tapware & Bottle trap |
Lecterns | - |
Standard AVTS Digital Lecterns | - |
Fume Cupboards | Yes |
Storage | System 7 underbench stage (Wedgewood Powdercoat) |
Fittings
Fittings
General Design Principles | - |
---|---|
Handrails & Balustrades | - |
More information about Fittings
Window Coverings
Blinds | - |
---|---|
Curtains | - |
External Awnings | - |
More information about Window Coverings
Signage
Design Principles | - |
---|---|
Macquarie University Signage and Wayfinding | - |
Door Signage | Number Sequential within block Ie. "PREPARATION" |
Security
Security
Security type / group | - |
---|---|
CCTV | - |
Access control | - |
Intruder detection | - |
Keying | Refer to Doors |
Acoustics
Acoustics
Noise level | - |
---|---|
Noise emittance | - |
Room to room | - |
Room acoustics | - |
Services
Ventilation
Natural ventilation | - |
---|---|
Supply air | - |
Exhaust | - |
Controls | - |
More information about Ventilation
Conditioning
Mechanical cooling | - |
---|---|
Mechanical heating | - |
Controls | - |
Other | - |
More information about Conditioning
Water
Portable cold water | - |
---|---|
Portable hot / warm water | - |
Non-portable water | - |
Other | - |
Drainage
Sanitary drainage | Connection
to one Handbasin at door. Include Bottle Trap Connection to lab sinks to perimeter benches of room |
---|---|
Trade waste | All drainage pipework to be HDPE |
Other | - |
More information about Drainage
Gas
Natural Gas | Required |
---|---|
Lab Gas | Consider
the following service points to workbenches and confirm requirements with Space
Type User Groups: Oxygen, Nitrogen, Hydrogen, Vacuum, Medium Pressure Compressed Air, High Pressure Compressed Air, and Helium |
Other | Consider Gas Detection and Emergency Stop Facilities |
Fire protection
Fire detection | - |
---|---|
Fire suppression | - |
EWIS | - |
Portable fire equipment | - |
Other | - |
More information about Fire protection
Illumination
Lighting / lux levels | - |
---|---|
Lighting controls | - |
Other | - |
More information about Illumination
Power
Type | - |
---|---|
Quantity | - |
Other | - |
Communication / AV
Voice | - |
---|---|
Data | - |
AV type | - |
WAP | - |
Other | - |
More information about Communication / AV
Vertical transport
Stairs | - |
---|---|
Lifts / escalators | - |
Materials hoists / other | - |
Commissioning
Commissioning
Building Commissioning | - |
---|---|
Services Commissioning | - |
As Built Documentation | - |