Gardeners Store
Space description
Designed a space for storage of gardening maintenance equipment.
Adjacencies
Room is to be accessible from external areas.
[ Expand all ]
Components
Planning
Planning
Site factors | - |
---|---|
Room and Spaces Planning Requirements | Room accessible from external areas |
Design occupancy | - |
Area | Approximately 4m2 |
Other | - |
Building fabric
General
General | - |
---|---|
Design principles | - |
Materials & finishes | - |
Proprietary items | - |
More information about building fabric General
Materials & Finishes
- | - |
---|---|
- | - |
- | - |
More information about Materials & Finishes
Roof
- | - |
---|---|
- | - |
External Walls
- | - |
---|---|
- | - |
- | - |
More information about External Walls
Internal Walls
Impact Resistance | Impact and Water Resistant |
---|---|
Fire Rating | - |
Wall Finish | - |
Other | - |
More information about Internal Walls
Floors
General Selection Requirements | - |
---|---|
Variations | - |
Preferred Material Selection | - |
Concrete | - |
Carpet | - |
Entry Floor Mats | - |
Floor Tiles | - |
Ceramic Tiles | - |
Resilient Floor Finishes | CC - Steel Trowelled Finished Concrete |
Other | Floor designed to enable hosing out of floor through external door. |
Underfloor Ventilation
- | - |
---|---|
- | - |
- | - |
More information about Underfloor Ventilation
Ceilings
Ceiling Finishes | - |
---|---|
Ceiling Heights | - |
Ceiling Selection | - |
Acoustic Ceilings | - |
Resistance | Impact resistant ceiling |
Non Combustible / Fire Rated | Non combustible ceiling linings are required |
Openings
Windows
Window Selection Requirements | Windows are not required for this space. |
---|---|
Glazing | When windows provided they must have obscure glazing and security Grills. |
Observation Windows | - |
Visual Privacy | Visual privacy is required from other spaces. |
Window Furniture | - |
Other | When windows provided they must have obscure glazing and security Grills. |
More information about Windows
Doors
Doors Type | Solid core external grade double doors or Galvanised steel roller shutter |
---|---|
Door Function | Lockable |
Fire / Acoustic Rated | - |
Frame Type | Steel framed |
Glazing | - |
Door Hardware | Lock type Storeroom lock Keying / locking Keyed to Differ (KD) Master keying Master keyed - Stores (ST) Other - |
Natural Lighting - Daylight | Not required |
Fixtures
Fixtures
General Design Principles | - |
---|---|
Amenities Fixtures | - |
Amenities for Mobility Impaired Persons | - |
Lecture Theatre Furniture & Fittings | - |
Cleaners Room & Store | - |
More information about Fixtures
Sanitary Fixtures
- | - |
---|---|
- | - |
Furniture
Furniture
General Design Principles | - |
---|---|
Recommended Furniture Selection | - |
Desk & Chair Selection | - |
More information about Furniture
Fixed Furniture
Door Entry Mats | - |
---|---|
Whiteboards | - |
Pinboards | - |
Notice Boards | - |
Projection Screens | - |
Kitchen & Tea Room Equipment | - |
Lecterns | - |
Standard AVTS Digital Lecterns | - |
Fume Cupboards | - |
Other | Heavy duty adjustable steel shelving minimum 0.9m wide 0.45m deep and 1.8m tall |
Fittings
Fittings
General Design Principles | - |
---|---|
Handrails & Balustrades | - |
More information about Fittings
Window Coverings
Blinds | - |
---|---|
Curtains | - |
External Awnings | - |
More information about Window Coverings
Signage
Design Principles | - |
---|---|
Macquarie University Signage and Wayfinding | - |
Door Signage | "STORE" |
Security
Security
Security type / group | D |
---|---|
CCTV | - |
Access control | - |
Intruder detection | - |
Keying | Refer to Doors |
Acoustics
Acoustics
Noise level | - |
---|---|
Noise emittance | - |
Room to room | - |
Room acoustics | - |
Services
Ventilation
Natural ventilation | Natural Ventilation of space via external grill having a free area of at least 5% of floor area. |
---|---|
Supply air | - |
Exhaust | - |
Controls | - |
More information about Ventilation
Conditioning
Mechanical cooling | - |
---|---|
Mechanical heating | - |
Controls | - |
Other | - |
More information about Conditioning
Water
Portable cold water | - |
---|---|
Portable hot / warm water | - |
Non-portable water | - |
Other | - |
Drainage
Sanitary drainage | - |
---|---|
Trade waste | - |
Other | - |
More information about Drainage
Gas
N gas | - |
---|---|
M gas | - |
Other | - |
Fire protection
Fire detection | - |
---|---|
Fire suppression | - |
EWIS | - |
Portable fire equipment | - |
Other | - |
More information about Fire protection
Illumination
Lighting / lux levels | - |
---|---|
Lighting controls | - |
Other | - |
More information about Illumination
Power
Type | - |
---|---|
Quantity | - |
Other | - |
Communication / AV
Voice | - |
---|---|
Data | - |
AV type | - |
WAP | - |
Other | - |
More information about Communication / AV
Vertical transport
Stairs | - |
---|---|
Lifts / escalators | - |
Materials hoists / other | - |
Commissioning
Commissioning
Building Commissioning | - |
---|---|
Services Commissioning | - |
As Built Documentation | - |